戻る
「早戻しボタン」を押すと検索画面に戻ります。 [閉じる]

コーパス検索結果 (1語後でソート)

通し番号をクリックするとPubMedの該当ページを表示します
1 the pressure self-focusing effect are to use beveled anvils and reach a very thin sample thickness at
2 (OR, 15.1; 95% CrI, 2.01-179), but not for a beveled approach (OR, 0.82; 95% CrI, 0.23-2.28).
3                                          The beveled approach seems to be safer than a straight appro
4         We report the discovery of 23 double-beveled bone tools from ~ 80,000-60,000-year-old archaeo
5      The electrochemical cell consisted of a beveled carbon fiber microdisk working electrode and a r
6 asma (LTP) probe as a way to prepare polymer bevel cross sections for secondary ion mass spectrometry
7                   These polyhedra lacked the beveled edges characteristic of wild-type AcMNPV polyhed
8           Surgical therapy included internal bevel gingivectomy combined with open flap debridement p
9                                Only internal bevel gingivectomy was performed for Mx since there was
10           The control group received reverse bevel incision only.
11 between the carbon dioxide laser and reverse bevel incision with respect to sulcular (P < or = 0.025)
12  palatal tissues were performed with inverse bevel incisions extending distally from teeth #5 and #12
13 0 000 procedures, and the probability that a beveled microincision increases the rate of endophthalmi
14 and a 0.9-mm bent Dewey tip with a 30-degree bevel (Microsurgical Technology Inc) were used for phaco
15 dian approach, and parallel orientation of a bevel needle are associated with lower PDPH rates.
16 array tip was filled with epoxy, followed by beveling of the tip of the array to form a deposited car
17 a simple method to prepare cross sections or bevels of polymer thin films for subsequent analysis by
18 ts of two sliding tubes: an inner one with a beveled opening that accommodates endoarterial tissue by
19 olume and delivery parameters (needle gauge, bevel orientation, insertion rate, depth, and infusion r
20 re done using a 20 gauge 0.9 mm bent reverse bevel phaco tip at constant vacuum (550 mm Hg), aspirati
21                 In general, the wedge-crater beveling protocol is shown to provide a powerful basis f
22 een 90 and 300 K using a unique wedge-crater beveling strategy that allows these parameters to be det
23 in each barrel into a sharp tip, followed by beveling the electrode tip to form an array (10-20 micro
24                                          The beveled tip of this needle robotically penetrates each S
25 n spray direct sampling tube equipped with a beveled tip.
26                                              Beveled-tip, 10,000 cpm MIVS system effectively and safe
27 ving solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 microm.
28                      Commercial needles have beveled tips with intentional cutting surfaces to ease i
29                         Orienting the needle bevel towards the outer edge of the cervix and keeping i
30                             The needle (with bevel up) was bent to 90 degrees and was inserted in the
31 ard the midperiphery, ensuring that only the bevel was inserted, considering it as a threshold of ins
32            If the whole length of the needle bevel was not inserted into the LN, substance backflush