戻る
「早戻しボタン」を押すと検索画面に戻ります。 [閉じる]

コーパス検索結果 (1語後でソート)

通し番号をクリックするとPubMedの該当ページを表示します
1 an electroluminescent panel using a graphite pencil.
2  triggered by the electrosurgical unit (ESU) pencil.
3 er sleeve was created and attached to an ESU pencil.
4     Subjects completed a standard, paper-and-pencil and a Web-based version of the same questionnaire
5                 The calculation is done with pencil and paper or a hand calculator.
6          This variability can be captured by pencil and paper questionnaires in which individuals rep
7                                              Pencils and papers are ubiquitous in our society and hav
8 ctrocardiogram (EKG) lead, nonactive "bovie" pencil, and nerve electrode monitor were placed in proxi
9 ed trauma to the area involving falling on a pencil as a child.
10 idating partnerships, and sharpening their e-pencils, as they prepare for the next tranche of researc
11           A relatively new technique, plasma pencil atmospheric mass spectrometry (PPAMS) was applied
12                                          The pencil beam of protons was produced by guided post-accel
13 The advent of energy-specific collimation in pencil beam scanning (PBS) proton therapy has led to an
14                  In this paper, we present a pencil beam scanning (PBS)-based ocular treatment soluti
15 r, most newer proton therapy centers provide pencil beam scanning treatments.
16  IMRT or proton therapy (uniform scanning or pencil beam scanning).
17 nt plans were repeatedly administered, using pencil beam scanning.
18 angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the
19          Observations obtained with a mobile pencil-beam Doppler radar revealed many previously unres
20  measure of diaphragmatic displacement via a pencil-beam navigator.
21  swine underwent single-fraction 30 to 40 Gy pencil-beam scanning proton therapy targeting the left v
22               All patients were treated with pencil-beam scanning.
23           We also discuss the sensitivity of pencil-beam surveys to the topology of large-scale struc
24 on of galaxies, clusters of galaxies, narrow pencil-beam surveys, and quasars, appear to be yielding
25               A deep redshift survey with a "pencil-beam" geometry of galaxies at the galactic poles
26 me-of-flight of waves travelling between two pencil beams and corrected for geometrical biases.
27                                         Such pencil beams do not constrain the physical extent of the
28  results from cross correlations of multiple pencil beams, containing over 1200 galaxies, indicate th
29      Using motion-sensitized two-dimensional pencil beams, septal shear waves were imaged at high tem
30  statistical problems associated with single pencil beams.
31                        Regular graphite/clay pencils can leave traces composed of percolated networks
32                                 Flexible toy pencils can leave traces that are essentially thin films
33 ng thermoluminescent dosimetric (TLD) and CT pencil chamber measurements.
34 king (eg, lit cigarette) and nonsmoking (eg, pencil) cues.
35 e carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignitio
36         One can envision many other types of pencil drawn paper electronic devices that can take on a
37 taining groups on office-copy papers between pencil-drawn electrodes.
38                         Among these devices, pencil-drawn graphite patterns (or combined with other c
39 oxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability
40 the 3D-electrode and the respective graphite pencil electrode tip using a high-voltage power supply.
41 H) onto MXene deposited onto the graphenized pencil fiber.
42 nd optimizations of base editors, rubber and pencil genome editing tools now promise to enable direct
43 divided cell with a constant current using a pencil graphite (C) anode and stainless-steel cathode in
44 tion of TRP on the electrochemically treated pencil graphite (ETPG) electrode surface at a suitable p
45 d by modifying the surface of the disposable pencil graphite (PGE) with physical adsorption to perfor
46 ic acid/poly-L-methionine-gold nanoparticles/pencil graphite electrode (DNA/PMET-AuNPs/PGE).
47 to prepare a low-cost and binder free MoS(2)-pencil graphite electrode (i.e., MoS(2)-PGE) for the ele
48 = Au or Cu) and poly xylenol orange modified pencil graphite electrode (p-XO/PGE) were used as workin
49 polycatechol-modified reduced graphene oxide/pencil graphite electrode (PC-rGO/PGE) to provide electr
50 tion of a DNA-based Au-nanoparticle modified pencil graphite electrode (PGE) biosensor for detection
51 ll lysates were covalently attached onto the pencil graphite electrode (PGE) by coupling agents of N-
52 ep procedure was used which includes coating pencil graphite electrode (PGE) by means of electro-poly
53       Gold nanorods (nano Au) deposited onto pencil graphite electrode (PGE) has been utilized for co
54 hemical impedance spectroscopy, a pretreated pencil graphite electrode (PGE) modified with multiwall
55 sing differential pulse voltammetry (DPV) at pencil graphite electrode (PGE) showed that both molecul
56   Electrochemical behavior of GelMA modified Pencil Graphite Electrode (PGE) that serve as a function
57 e bases was studied electrochemically with a pencil graphite electrode (PGE) using differential pulse
58 nted sensor was fabricated on the surface of pencil graphite electrode (PGE) via one-step electropoly
59 try (DPV) in combination with the disposable pencil graphite electrode (PGE) was progressed for sensi
60 e (rGO) and gold nanoparticles (AuNPs)-based pencil graphite electrode (PGE).
61 P/MWCNT/Chi hybrid bionanocomposite modified pencil graphite electrode (PGE).
62 ination of caffeic acid (CA) on a disposable pencil graphite electrode (PGE).
63 inuous cyclic voltammetric on the surface of pencil graphite electrode (PGE).
64                                   Pretreated pencil graphite electrode (PPGE) was also used for the d
65 ting WO(3)/g-C(3)N(4) nanocomposite modified Pencil graphite electrode to detect an organophosphate i
66 template imprinted polymer nanofilm-modified pencil graphite electrode was fabricated for the simulta
67                                  Herein, the pencil graphite electrode was initially spin coated with
68                                   Finally, a pencil graphite electrode was modified with carbon nanot
69     This system, when casted on the tip of a pencil graphite electrode, responded a highly sensitive
70 ctrochemically fabricated on C-dots modified pencil graphite electrode.
71 olymerization on the surface of the modified pencil graphite electrode.
72 od onto the surface of vinyl silane modified pencil graphite electrode.
73  based peptide nanoparticles (PNPs) modified pencil graphite electrodes (PGEs) for construction of el
74 ced graphene oxide (rGO) modified disposable pencil graphite electrodes (PGEs) were developed herein
75 lectropolymerized polypyrrole (PPy) modified pencil graphite electrodes (PPy/PGE).
76 ized on the surface of vinyl silane modified pencil graphite electrodes by activator regenerated by a
77  this modified electrode with other modified pencil graphite electrodes like single layered acrylamid
78 ore-shell nanostructures on a cost-effective pencil graphite substrate.
79 te electrodeposited copper nanostructures on pencil graphite substrate.
80 on and substrate adhesion resistance against pencil hardness, dry/wet scribed tape peel adhesion and
81 n example being the writing of a name with a pencil held between the toes or teeth.
82 study supports including a study-logo pen or pencil in a second questionnaire mailing to nonresponden
83 ints at no added cost through inclusion of a pencil in the second mailing.
84            The patients were given paper-and-pencil instruments that assessed current severity of hai
85 h damage simulated by artificial AE sources (Pencil lead break) and low-velocity impacts.
86 oyl esters was developed using the activated pencil lead electrode (APLE).
87 gies were investigated for activation of the pencil lead electrode and the results show that the pote
88 itions for electrochemical activation of the pencil lead electrode.
89 s made of a hemispherical agar embedded with pencil lead fragments simulating as FBs.
90                                              Pencil lead was used to fabricate a graphite-based elect
91 ) as an amperometric redox indicator, with a pencil lead working electrode, in conjunction with a Pt
92  and real samples, utilizing enzyme-modified pencil leads (PL) as effective electrochemical biosensor
93                                          The pencil-like and stepwise nano-pillars are, however, easi
94 cting with a solid target and converted to a pencil-like narrow-band beam using a compact magnet-base
95  cross-sectional geometries including cone-, pencil-like, and stepwise are prepared from anodized alu
96 ter predictor than the traditional paper-and-pencil measure of cognitive risk for depression (Cogniti
97 ponses to reward stimuli predict a paper-and-pencil measure of temporal discounting.
98 s context, previous work involving paper-and-pencil measures of cognition has demonstrated that a thr
99  composite scores and conventional paper-and-pencil measures of visuo-constructional, procedural, and
100 pain are preferable to traditional paper-and-pencil measures.
101 bic barriers on paper, while micromechanical pencils (mounting 4B graphite leads, 0.5 mm in diameter)
102 n) who underwent noncontrast-enhanced matrix pencil MRI and lung function tests before and immediatel
103  reveal clinical symptoms earlier than paper-pencil NP tests.
104                                              Pencil-on-paper devices are low-cost, extremely simple a
105                                 In addition, pencil-paper-based antennas, two-dimensional (2D) and th
106               Herein, we report a variety of pencil-paper-based on-skin electronic devices, including
107                   It was hypothesized that a pencil-point conical-shaped needle would cause less dama
108                                              Pencil-point needle designs may be particularly applicab
109 e was subsequently designed with a removable pencil-point trocar and a side arm for the dialysis tubi
110                                    We used a pencil probe (diameter 5 mm) to measure electrical imped
111 ctiveness of home-based therapies (including pencil push-ups and home computer therapy) compared with
112                                              Pencil push-ups and use of accommodative targets have a
113  the effectiveness of base-in prism glasses, pencil push-ups, and vision therapy in reducing the sign
114 rn this changeability as well as a paper-and-pencil questionnaire.
115 diagnostic interview and completed paper-and-pencil questionnaires on presentation for treatment.
116                                The paper-and-pencil Rey-Osterrieth Complex Figure (ROCF) copy task ha
117             Leptotrichia spp. are anaerobic, pencil-shaped, Gram-negative rods that are part of the n
118                 As in the previous paper-and-pencil studies, most participants designed diverse portf
119               Building on previous paper-and-pencil studies, we developed a computer tool that aimed
120 ules, gas-phase ozone generated by a mercury pencil-style lamp reacts with either 10 microM oleic aci
121           Cross-sectional, multicenter paper-pencil survey on personal and work-related characteristi
122 70 years and older suggests that a paper and pencil test assessing higher order visual processing ski
123 view [UFOV] subset 2); Trails B, a paper and pencil test of visual processing speed also involving pr
124 ntly higher accuracy than standard paper-and-pencil tests (that is, Mini-Mental State Examination, Mo
125 y with performance in conventional paper and pencil tests of executive functions for patients with PD
126 sucking; or sucking on objects such as pens, pencils, thread, or toothpicks.
127 ees C +/- 1.2 degrees C (P = 0.002), "bovie" pencil tip 90 degrees C +/- 9 degrees C (P < 0.001), and
128 We inserted glass, porcelain, plastic, wood, pencil tip, chicken bone, iron, walnut shell, and fishbo
129 essive carbon dioxide surrounding the active pencil tip.
130 ugh the coupling of a low-temperature plasma pencil to an atmospheric mass spectrometer.
131                                              Pencil traces drawn on print papers are shown to functio
132             In contrast, the sea star or the pencil urchin orthologs of other ACD factors were consis
133 actor Vasa during early embryogenesis of the pencil urchin, an ancestral type of sea urchin.
134 by participants in the traditional paper-and-pencil version may influence performance.
135 cohort, response was 43% with inclusion of a pencil versus 24% without one (p = 0.02).
136                   The additional cost of the pencil was compensated for by the reduced number of nonr
137 d two US trials in which a study-logo pen or pencil was randomly included in a second questionnaire m
138               However, inclusion of a pen or pencil, which may be a facilitating factor as well as a
139 -reconstruction methods, one applicable to a pencil X-ray beam scanning through a region of interest,

 
Page Top