戻る
「早戻しボタン」を押すと検索画面に戻ります。

今後説明を表示しない

[OK]

コーパス検索結果 (1語後でソート)

通し番号をクリックするとPubMedの該当ページを表示します
1 he maximal reactivity observed for the assay calibrator.
2  method can be adapted for use with any dose calibrator.
3 n a mixed sample can be assayed using a dose calibrator.
4 able instrument, the ionization chamber dose calibrator.
5 racts be established by dPCR prior to use as calibrator.
6 based on volume as well as on the local dose calibrator.
7 ed candidate material for an Aspergillus DNA calibrator.
8 reement when that panel was used as a common calibrator.
9  dose of 600 mg/d for 10 days) was used as a calibrator.
10 of a mouse anti-human fVIIIAb as a surrogate calibrator.
11  mRNA levels in untreated control samples as calibrator.
12 re it also serves as the primary photometric calibrator.
13 thyl chroman-2-carboxylic acid (Trolox) as a calibrator.
14 rget material and is independent of external calibrators.
15 of RT-PCR data depend on the use of external calibrators.
16 andard deviation, was less than 9.2% for all calibrators.
17 occur when synthesized peptides were used as calibrators.
18 radionuclides in several commercial activity calibrators.
19 t of the positive human plasma-derived assay calibrators.
20      Index values (specimen absorbance value/calibrator absorbance value) for the screening dilution
21 yptic and cleavable SIL peptides as internal calibrators across various bottom-up assays (i.e., denat
22  investigation examined the accuracy of dose calibrator activity measurement of the beta-emitting rad
23 ucleic acids without the need of an external calibrator and a greater resistance to inhibitors than r
24 nstants are only correct for a specific dose calibrator and setting, the method can be adapted for us
25                                          The calibrator and the human plasma anti-fVIIIAb were captur
26 positive human plasma for the manufacture of calibrators and controls for diagnostic assays.
27  6329/10), and used to prepare working assay calibrators and controls, which supported an assay quant
28 mplified DNA lack standards for use as assay calibrators and controls.
29             We used internal oligonucleotide calibrators and custom analysis software to improve smal
30 es, calibration approaches utilizing various calibrators and internal standards (I.S.) have been deve
31 -inhibited BuChE were synthesized for use as calibrators and internal standards, respectively.
32 rate and precise by the repeated analysis of calibrators and quality control samples in urine and pla
33 d storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highl
34 bration factors for NIST-maintained activity calibrators and secondary standard ionization chambers t
35   The final method using recombinant protein calibrators and stable isotope labeled (SIL) peptide int
36  results obtained with the chimeric antibody calibrators and the positive human plasma calibrators wa
37  for internal calibration (i.e., as internal calibrators) and external calibration (i.e., as internal
38 yl-1-chroman-2-carboxylic acid (Trolox) as a calibrator; and phosphate buffer (pH 7.0) as a solvent.
39 d settings for the NIST Capintec CRC-12 dose calibrator are (631+/-4) x 10 and (621+/-3) x 10 for the
40 d epoxy mock syringe source used in activity calibrators as a long-lived substitute for (18)F.
41 ssignments by bottom-up assays using peptide calibrators, as well as protein calibrators, given that
42 9)Zr activity was measured in a central dose calibrator before delivery.
43 over the course of 22 sample sets containing calibrators, blanks, and quality control samples.
44 ecision through the use of isotope dilution, calibrator bracketing, and gravimetric measurements.
45                                          The calibrator can be used to standardize aspergillosis diag
46 oss different assays; use of a noncommutable calibrator can reduce agreement among laboratories.
47                Selection of the quantitative calibrator, commercially prepared primers and probes, an
48 hy (HPLC)-grade water, defined as the lowest calibrator concentration, was 25 pg/mL in a small, 500 m
49                  Serial dilution of each RNA calibrator demonstrated a 5 log linear dynamic range (5
50  standardize 90Y sources to establish a dose calibrator dial setting for accurate calibration of clin
51 he local dose calibrator to the central dose calibrator, differences between the local activity assay
52        The identical treatment of sample and calibrators eliminates the need for subtracting the proc
53  of the relative response ratios in activity calibrators enabled the equivalent (18)F activity to be
54 ng AAA to verify purities of protein/peptide calibrators ensures accurate quantitation.
55 75 x 70 and 775 x 100 on a radionuclide dose calibrator for 90Y measurements.
56 ombination on the standard radionuclide dose calibrator for calibration of 90Y radiopharmaceuticals.
57 eveloped an automated, permeation tube-based calibrator for elemental and oxidized mercury, and we in
58 standard) was introduced in 2016 as a common calibrator for improving the harmonization of BKV nuclei
59  substitution rates in intronic regions as a calibrator for neutral change, we found a strong avoidan
60 r, CD4 protein has been used as a biological calibrator for quantification of other surface and intra
61  competitive molecule successfully served as calibrator for quantification, matrix normalisation, and
62 1 transcript-specific in vitro-generated RNA calibrators for absolute quantitation.
63 of plasmid DNA (pDNA) and genomic DNA (gDNA) calibrators for the quantification of MON 810 maize was
64 sing peptide calibrators, as well as protein calibrators, given that absolute accuracy was not univer
65                                    While the calibrator has limitations, it was able to routinely inj
66 o quantify viral genomes without requiring a calibrator; however, neither can currently compete with
67 g external calibration for surrogate protein calibrators (i.e., recombinant proteins) to produce inac
68 se results indicate that the use of a common calibrator improved the agreement between the two assays
69 surrogate source to calibrate their activity calibrators in a way that is consistent with the recent
70 ly available calibration source for activity calibrators in a way that is traceable to the national s
71                              Dilution of the calibrators in total RNA from 1 x 10(3) non-WT1-expressi
72 dial setting for a given manufacturer's dose calibrator is required for accurate measurements.
73 res external calibration; a common choice of calibrator is the 8E5 cell line, which is assumed to be
74 hetic calibrators were identical to those of calibrators isolated from bone.
75  anti-P66 antibodies matched the assay index calibrator manufactured with human Toxo IgM-positive pla
76 gestion stringency and indicates why protein calibrators may not be commutable in bottom-up protein a
77  sample can be calculated from a single-dose calibrator measurement.
78                                         Dose calibrator measurements were evaluated using National In
79 0)Y in a 10-mL syringe geometry with 30 dose calibrator models from 3 different manufacturers.
80 polymerase chain reaction (qPCR) assays with calibrators now traceable to the First World Health Orga
81  OD was normalized (OD-n; OD-n = specimen OD/calibrator OD).
82 pecial care is taken to quantifying E with a calibrator of nature and matrix highly similar to the sa
83 ermined in this way are necessary as primary calibrators of reference measurement systems in order to
84 ata of the gene of interest relative to some calibrator or internal control gene.
85 riable regions and human constant regions as calibrators or controls in immunoassays.
86                                              Calibrator readings of 90Y sources in glass and plastic
87 IV IgG contents between the controls and the calibrator reagents was exploited to monitor individual
88 ch testing center using its own quantitative calibrators, reagents, and nucleic acid extraction metho
89 icated that the ferrous sulfate heptahydrate calibrator recommended by Benzie and Strain, the FRAP as
90                          The use of a common calibrator reduced the between-assay variability to some
91 ments of radionuclides using commercial dose calibrators requires that the correct dial setting (or c
92  897 x 100 for Atomlab, CRC, and Mark V dose calibrators, respectively.
93                                     The dose calibrator response to 90Y radiation was linear within a
94                                     The dose calibrator response was also studied on 90Y sources at v
95 d from 188Re decay when calculating the dose calibrator response.
96        We implement a meta-analysis based on calibrator samples to characterize the coefficient of va
97                      At the recommended dose calibrator setting for the measurement of 67Cu, at which
98                                     The dose calibrator setting for the medical radionuclide 188Re (a
99 need for experimental determinations of dose calibrator settings in the geometry in which the measure
100                     Analysis of controls and calibrator specimen for all 343 runs showed a coefficien
101                               Other internal calibrators such as 18S-ribosomal RNA (18S-RNA) have als
102  of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurre
103                               By introducing calibrator synthetic oligonucleotides during library pre
104       The use of a matrix-adapted control as calibrator to compensate the resulting C(T) bias allowed
105          After calibration of the local dose calibrator to the central dose calibrator, differences b
106 was developed using synthetic PYD and DPD as calibrators to analyze free and total PYD and DPD in uri
107 ectly compared in several models of activity calibrators to determine empirically the relative respon
108 ion will need to be controlled with suitable calibrators to maximize agreement between laboratories.
109       As clinical laboratories worldwide use calibrators traceable to the primary standard to harmoni
110 d uncertainty of about 0.8% for the activity calibrators used in this study.
111 012, Ortho Clinical Diagnostics adjusted the calibrator values for Vitros Chemistry Products BuBc Sli
112                                         Dose calibrator variability was less than 1%, although there
113 dy calibrators and the positive human plasma calibrators was > or =0.985.
114 umentation, including the survey meter, dose calibrator, well counter, intraoperative probe, organ ("
115 ectroscopic characteristics of the synthetic calibrators were identical to those of calibrators isola
116 d from a hemophilia A subject, was used as a calibrator with a detectability limit of 40 (+/-1.5) pM.
117 and oxidized mercury, and we integrated this calibrator with atmospheric mercury instrumentation (Tek
118 s and two "hybrid" approaches (i.e., protein calibrator with SIL-peptide or SIL-extended-peptide I.S.

WebLSDに未収録の専門用語(用法)は "新規対訳" から投稿できます。
 
Page Top